{"id":6822,"date":"2026-11-26T17:11:45","date_gmt":"2026-11-26T08:11:45","guid":{"rendered":"https:\/\/cm-plus.co.jp\/en\/?post_type=column&#038;p=6822"},"modified":"2026-11-26T17:12:27","modified_gmt":"2026-11-26T08:12:27","slug":"2026_1126-2","status":"publish","type":"column","link":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/","title":{"rendered":"Key Regulatory Updates on Vietnam GMP Standards"},"content":{"rendered":"<p><img decoding=\"async\" class=\"alignnone wp-image-6823 size-full\" src=\"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1.jpg\" alt=\"\" width=\"100%\" height=\"517\" srcset=\"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1.jpg 1000w, https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1-300x155.jpg 300w, https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1-768x397.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<p>Vietnam requires WHO-GMP as the baseline standard for pharmaceutical manufacturing. Based on the product and its intended use, they also apply and recognize EU-GMP, PIC\/S-GMP, and equivalent SRA standards, such as Japan&#8217;s J-GMP and the US cGMP. The specific application rules are determined by the Circular of the Ministry of Health of Vietnam, which is the basic law.<br \/>\nOn November 1, 2026, the Ministry of Health <strong>(MOH) of Vietnam<\/strong> officially issued Circular No. 45\/2026\/TT-BYT, amending and supplementing several articles of Circular No. 28\/2025\/TT-BYT on Good Manufacturing Practices for medicinal products and medicinal materials (GMP).<br \/>\nTaking effect on January 1, 2027, this document introduces profound changes in technical standards, facility design, change control, and compliance roadmaps for pharmaceutical manufacturers, medicinal material processors, and hospitals in Vietnam.<br \/>\nFrom the perspective of a pharmaceutical engineering consultancy and project management firm, CM Plus <strong>Vietnam Co.,Ltd.<\/strong> summarizes and analyzes the core highlights of Circular 45\/2026\/TT-BYT to help investors and enterprises proactively plan their facility upgrades and quality management systems.<\/p>\n<p><span style=\"font-size: 14pt;\"><strong>\u25a0 Major updates from the previous circular<\/strong><\/span><\/p>\n<p><strong>1. Expanding GMP Scope to Radiopharmaceuticals and Investigational Medicinal Products<\/strong><\/p>\n<p>One of the landmark updates in Circular 45\/2026\/TT-BYT is the codification of GMP standards for two specialized sectors that previously lacked detailed provisions within the general framework:<\/p>\n<div style=\"padding-left: 1em;\">\n<p>\u25cf Production of Radiopharmaceuticals at Healthcare Facilities: The Circular adds definitions and requires hospitals and healthcare institutions producing radioisotopes via cyclotrons, as well as synthesizing and compounding radiopharmaceuticals from such sources, to comply with the GMP principles in Annex XIII (based on IAEA and WHO guidelines). The mandatory compliance deadline for these facilities is November 1, 2028.<\/p>\n<p>\u25cf Investigational and Clinical Trial Medicinal Products: Facilities manufacturing drugs for clinical trials are now required to implement WHO-GMP in accordance with the new Annex XII. This mandates strict controls over traceability, blinding operations, risk management, and record retention for up to 30 years for data submitted for marketing authorization.<\/p>\n<\/div>\n<p><strong>2. Tightening Facility Design Standards and Dedicated Production Lines<\/strong><\/p>\n<p>Regarding master planning, architectural design, and utility systems (HVAC, water treatment), Circular 45\/2026\/TT-BYT establishes stringent requirements to completely eliminate cross-contamination risks:<\/p>\n<div style=\"padding-left: 1em;\">\n<p>\u25cf Strictly Dedicated Production Lines: Medicinal products and materials containing beta-lactam antibiotics (Penicillins, Cephalosporins, Penems, etc.), cytotoxic drugs, contraceptive sex hormones, vaccines, biologicals containing live microorganisms, and radiopharmaceuticals must be manufactured on dedicated production lines (completely segregated facilities, production equipment, and utility systems).<\/p>\n<p>\u25cf Clear Separation of GMP Standards for Traditional Medicines and Medicinal Materials:<\/p>\n<\/div>\n<div style=\"padding-left: 2em;\">\n<p>\u25c7 Annex VI clearly distinguishes GMP standards for traditional medicines in traditional dosage forms (extracts, pills, powders, medicinal wines, tinctures \u2013 Part I) and modern dosage forms (tablets, capsules, granules \u2013 Part II). Notably, for modern dosage forms, the final processing area for non-sterilized herbal powders and the final concentration stage of extracts must meet at least Grade D (ISO 8) cleanroom standards.<\/p>\n<p>\u25c7 Annex VII standardizes a separate set of GMP principles for medicinal material preliminary processing and manufacturing facilities, requiring unidirectional layouts, dust control, and specialized waste treatment.<\/p>\n<\/div>\n<p><strong>3. Controlled Flexibility for Co-manufacturing Health Supplements<\/strong><\/p>\n<p>Circular 45\/2026\/TT-BYT clarifies the technical boundaries allowing pharmaceutical plants to optimize line capacity while ensuring quality and safety:<\/p>\n<div style=\"padding-left: 1em;\">\n<p>\u25cf Facilities manufacturing exclusively non-prescription chemical drugs are permitted to produce herbal medicines, traditional medicines, and health supplements of corresponding dosage forms (excluding health supplements containing live microorganisms \u2013 probiotics).<\/p>\n<p>\u25cf Facilities with dedicated lines for biological drugs\/materials containing probiotics are permitted to manufacture materials or health supplements of corresponding dosage forms containing the same probiotic strains (or in combination with vitamins).<\/p>\n<p>\u25cf The Vietnam Food Administration (VFA) will take the lead in inspecting GMP compliance for health supplement manufacturing activities conducted on pharmaceutical production lines (harmonized with amendments to Circular 18\/2019\/TT-BYT).<\/p>\n<\/div>\n<p><strong>4. Strengthening &#8220;Change Control&#8221; Mechanisms and On-site Inspections<\/strong><\/p>\n<p>Under Article 8 (amending Article 11), Change Control regulations are detailed into specific tiers, directly impacting plant renovation, upgrading, and expansion projects:<\/p>\n<div style=\"padding-left: 1em;\">\n<p>\u25cf Changes Requiring On-site Inspection Prior to Operation: These include relocating or adding manufacturing plants, warehouses (raw materials, primary packaging, finished products), or microbiological testing laboratories within the same business location, as well as expanding or making major structural modifications to facilities. In particular, for sterile product and vaccine manufacturers, even partial line renovations, major equipment replacements, or modifications to utility\/HVAC design principles affecting the production environment require submitting a Change Report (Form No. 06) for on-site assessment or validation by the regulatory authority.<\/p>\n<p>\u25cf Strict Sanctions for GMP Deficiencies: The Circular classifies compliance into 4 levels (Annex IX). If a facility falls into Level 4 (having 1 or more critical deficiencies, or 7 or more major deficiencies on a single line), within 05 working days, the regulatory authority will issue a notice of GMP non-compliance, suspend operations, and potentially revoke the Certificate of Eligibility for Pharmacy Business.<\/p>\n<\/div>\n<p><strong>5. Facilitating the Maintenance of EU-GMP Recognition<\/strong><\/p>\n<p>To minimize supply chain disruptions for internationally certified plants, the Circular allows facilities already published as meeting EU-GMP or equivalent standards (issued by Stringent Regulatory Authorities &#8211; SRA) to maintain their published compliance status upon certificate expiration, provided they have submitted a renewal publication dossier or provided valid self-lookup results from the issuing authority&#8217;s English database along with a verification link.<\/p>\n<p><span style=\"font-size: 14pt;\"><strong>\u25a0 Recommendations from CM Plus<\/strong><\/span><\/p>\n<p>With the effective date of January 1, 2027 approaching, pharmaceutical enterprises and healthcare institutions should promptly initiate the following preparations:<\/p>\n<div style=\"padding-left: 1em;\">\n<p>1. Conduct a Comprehensive GAP Assessment: Benchmark existing facilities, HVAC systems, water treatment systems, and Standard Operating Procedures (SOPs) against the new Annexes (especially Annexes VI, VII, XII, and XIII).<\/p>\n<p>2. Plan Renovations with Regulatory Alignment: All projects involving warehouse expansion, microbiology cleanroom renovation, utility upgrades, or line repurposing must be supported by thorough technical documentation to satisfy the Ministry of Health&#8217;s change control and on-site inspection requirements.<\/p>\n<p>3. Initiate Roadmaps for Nuclear Medicine Facilities: Hospitals operating cyclotrons for radiopharmaceutical production must immediately launch plans to upgrade cleanrooms (achieving Grade A in a Grade B background for critical aseptic operations) and radiation safety systems ahead of the November 1, 2028 deadline.<\/p>\n<\/div>\n<p><em>As a specialized consultancy in engineering design, project management, and validation for pharmaceutical plants under WHO-GMP, PIC\/S-GMP, and EU-GMP standards, CM Plus Vietnam Co.,Ltd. stands ready to partner with enterprises in assessing current facilities, optimizing technical solutions, and ensuring seamless compliance with the latest regulatory requirements.<\/em><\/p>\n<hr \/>\n<p><strong>Author<\/strong><\/p>\n<div style=\"display: flex; align-items: flex-start; margin-top: 10px; margin-bottom: 30px;\">\n<div style=\"width: 120px; min-width: 120px; margin-right: 20px; text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-6824 size-full\" style=\"margin: 0 auto; display: block;\" src=\"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Ms.Loan_.jpg\" alt=\"\" width=\"375\" height=\"500\" srcset=\"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Ms.Loan_.jpg 375w, https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Ms.Loan_-225x300.jpg 225w\" sizes=\"(max-width: 375px) 100vw, 375px\" \/><\/div>\n<div style=\"flex: 1; min-width: 0; text-align: justify;\"><strong>Ms. Bui Thi Hong Loan<\/strong><br \/>\n<strong>GMP &amp; Validation Assistant, CM Plus Vietnam Co., Ltd.<br \/>\n<\/strong>Ms. Loan has over 10 years of experience in the pharmaceutical industry. She began her career at Sanofi Synthelabo Pharmaceutical Joint Stock Company in 2010 and later joined Glomed Pharmaceutical Co., Ltd. \u2013 an Abbott affiliate in 2018. Through her roles in Quality Control (QC) and Quality Assurance (QA), she developed solid expertise in pharmaceutical Good Manufacturing Practice (GMP) and quality management systems.<br \/>\nSince joining CM Plus Vietnam Co., Ltd. in May 2022, Ms. Loan has been providing GMP consulting and validation support for pharmaceutical manufacturing facilities. She is involved in various GMP compliance and validation projects, helping clients meet regulatory requirements and enhance the quality of their manufacturing operations.<\/div>\n<\/div>\n<p><strong style=\"text-align: justify;\">About GMP Platform<\/strong><span style=\"text-align: justify;\"> (<\/span><span style=\"color: #e04040;\"><a style=\"color: #e04040;\" href=\"https:\/\/www.gmp-platform.com\/\" target=\"_blank\" rel=\"noopener\">https:\/\/www.gmp-platform.com\/<\/a><\/span><span style=\"text-align: justify;\">)<\/span><\/p>\n<div style=\"display: flex; align-items: flex-start; margin-top: 10px;\">\n<div style=\"width: 120px; min-width: 120px; margin-right: 20px; text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-6287\" style=\"margin: 0 auto; display: block;\" src=\"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/06\/67a6e7abd7eed66835c60503b99f2499.png\" alt=\"\" width=\"111\" height=\"62\" \/><\/div>\n<div style=\"flex: 1; min-width: 0; text-align: justify;\">GMP Platform is a free GMP-related information portal established in 2012 and operated by CM Plus Corporation. Built on CM Plus\u2019s founding principle of addressing quality-related issues in life science facilities, the site provides practical, expert-led information for life science manufacturing professionals. With more than 26,000 registered users, GMP Platform introduces the latest GMP-related regulations and trends in Japan, the United States, Europe, and other regions, along with translated and explanatory articles on guidelines, technical articles, seminars, e-learning programs, and books. It is widely used by professionals involved in GMP compliance, quality assurance, and the development of effective quality systems.Please use Google Translate or similar translation tools to read more articles originally published in Japanese.<br \/>\n*If you are using Google Chrome, right-click and select &#8220;Google Translate&#8221; on the article.<\/div>\n<\/div>\n","protected":false},"featured_media":6823,"template":"","columncat":[61],"columntag":[],"keywords":[11],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Key Regulatory Updates on Vietnam GMP Standards\uff5cCM Plus<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Key Regulatory Updates on Vietnam GMP Standards\uff5cCM Plus\" \/>\n<meta property=\"og:description\" content=\"Vietnam requires WHO-GMP as the baseline standard for pharmaceutical manufacturing. Based on the product and its intended use, they also apply and recognize EU-GMP, PIC\/S-GMP, and equivalent SRA standards, such as Japan&#8217;s J-GMP and the US cGMP. The specific application rules are determined by the Circular of the Ministry of Health of Vietnam, which is the basic law. On November 1, 2026, the Ministry of Health (MOH) of Vietnam officially issued Circular No. 45\/2026\/TT-BYT, amending and supplementing several articles of Circular No. 28\/2025\/TT-BYT on Good Manufacturing Practices for medicinal products and medicinal materials (GMP). Taking effect on January 1, 2027, this document introduces profound changes in technical standards, facility design, [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/\" \/>\n<meta property=\"og:site_name\" content=\"CM Plus\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-26T08:12:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2024\/05\/ogp.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"517\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/\",\"url\":\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/\",\"name\":\"Key Regulatory Updates on Vietnam GMP Standards | CM Plus\",\"isPartOf\":{\"@id\":\"https:\/\/cm-plus.co.jp\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1.jpg\",\"datePublished\":\"2026-11-26T08:11:45+00:00\",\"dateModified\":\"2026-11-26T08:12:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#primaryimage\",\"url\":\"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1.jpg\",\"contentUrl\":\"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1.jpg\",\"width\":1000,\"height\":517},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u30db\u30fc\u30e0\",\"item\":\"https:\/\/cm-plus.co.jp\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Column\",\"item\":\"https:\/\/cm-plus.co.jp\/en\/column\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Key Regulatory Updates on Vietnam GMP Standards\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cm-plus.co.jp\/en\/#website\",\"url\":\"https:\/\/cm-plus.co.jp\/en\/\",\"name\":\"CM Plus\",\"description\":\"Your Partner in Facility Construction, Quality Assurance, and GMP Education\/Training\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cm-plus.co.jp\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Key Regulatory Updates on Vietnam GMP Standards\uff5cCM Plus","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/","og_locale":"en_US","og_type":"article","og_title":"Key Regulatory Updates on Vietnam GMP Standards\uff5cCM Plus","og_description":"Vietnam requires WHO-GMP as the baseline standard for pharmaceutical manufacturing. Based on the product and its intended use, they also apply and recognize EU-GMP, PIC\/S-GMP, and equivalent SRA standards, such as Japan&#8217;s J-GMP and the US cGMP. The specific application rules are determined by the Circular of the Ministry of Health of Vietnam, which is the basic law. On November 1, 2026, the Ministry of Health (MOH) of Vietnam officially issued Circular No. 45\/2026\/TT-BYT, amending and supplementing several articles of Circular No. 28\/2025\/TT-BYT on Good Manufacturing Practices for medicinal products and medicinal materials (GMP). Taking effect on January 1, 2027, this document introduces profound changes in technical standards, facility design, [&hellip;]","og_url":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/","og_site_name":"CM Plus","article_modified_time":"2026-11-26T08:12:27+00:00","og_image":[{"width":1000,"height":517,"url":"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2024\/05\/ogp.png","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/","url":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/","name":"Key Regulatory Updates on Vietnam GMP Standards | CM Plus","isPartOf":{"@id":"https:\/\/cm-plus.co.jp\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#primaryimage"},"image":{"@id":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#primaryimage"},"thumbnailUrl":"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1.jpg","datePublished":"2026-11-26T08:11:45+00:00","dateModified":"2026-11-26T08:12:27+00:00","breadcrumb":{"@id":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#primaryimage","url":"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1.jpg","contentUrl":"https:\/\/cm-plus.co.jp\/en\/wp-content\/uploads\/2026\/11\/Vietnam-GMP_1.jpg","width":1000,"height":517},{"@type":"BreadcrumbList","@id":"https:\/\/cm-plus.co.jp\/en\/column\/gmp\/2026_1126-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u30db\u30fc\u30e0","item":"https:\/\/cm-plus.co.jp\/en\/"},{"@type":"ListItem","position":2,"name":"Column","item":"https:\/\/cm-plus.co.jp\/en\/column\/"},{"@type":"ListItem","position":3,"name":"Key Regulatory Updates on Vietnam GMP Standards"}]},{"@type":"WebSite","@id":"https:\/\/cm-plus.co.jp\/en\/#website","url":"https:\/\/cm-plus.co.jp\/en\/","name":"CM Plus","description":"Your Partner in Facility Construction, Quality Assurance, and GMP Education\/Training","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cm-plus.co.jp\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/column\/6822"}],"collection":[{"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/column"}],"about":[{"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/types\/column"}],"version-history":[{"count":11,"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/column\/6822\/revisions"}],"predecessor-version":[{"id":6826,"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/column\/6822\/revisions\/6826"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/media\/6823"}],"wp:attachment":[{"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/media?parent=6822"}],"wp:term":[{"taxonomy":"columncat","embeddable":true,"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/columncat?post=6822"},{"taxonomy":"columntag","embeddable":true,"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/columntag?post=6822"},{"taxonomy":"keywords","embeddable":true,"href":"https:\/\/cm-plus.co.jp\/en\/wp-json\/wp\/v2\/keywords?post=6822"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}